Home > 1000 kg of steam at a pressure of 16 bar and 0.9 dry is generated by a boiler and it enters the super heater

1000 kg of steam at a pressure of 16 bar and 0.9 dry is generated by a boiler and it enters the super heater

About Us

Zozen Boiler main products include gas&oil boiler, coal-fired boiler, biomass boiler, thermal fluid heater and other series of more than 400 varieties of specifications.
Contact us for Email:[email protected]

Our Main Product

our main boilers
wns boiler picture

1-20 ton gas/oil fired boiler

Price: $1-$99999/set

Capacity: 1-20 ton/h

Pressure: 0.7-2 Mpa

Fuel: Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.

Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

szs boiler picture

7-70 MW gas/oil fired hot water boiler

Price: $1-$999999/set

Capacity: 7-70 MW

Pressure: 1.0-1.6 Mpa

Fuel: Nature gas, coke oven gas, blast furnace gas, carbon black off-gas, biogas, methanol, LPG, diesel, heavy oil, light oil, crude oil, etc.

Industries: Heat supplying, hospital, colleges and universities.

szl boiler picture

2.8-29mw coal fired boiler

Price: $1-$999999/set

Capacity: 2.8-29mw

Pressure: 1.0-1.25 Mpa

Fuel: Bituminous coal, lean coal, anthracite

Industries: Heating, hotels, schools, hospitals

yyw boiler picture

horizontal thermal fluid heater

Price: $1-$99999/set

Capacity: 700 - 14000 kw

Pressure: 0.8 - 1.0 Mpa

Fuel: natural gas, coke oven gas, bio-gas,liquid propane gas, diesel, heavy oil, light oil, crude oil

Industries: Petroleum, chemical, chemical fiber, pharmaceutical, textile printing and dyeing, building materials, wood processing, vegetable oil processing and other industries

wns boiler picture

1-20 ton biomass fired boiler

Price: $1-$999999/set

Capacity: 1-20 ton/h

Pressure: 0.7-2.5 Mpa

Fuel: Biomass particles

Industries: Heating, chemical, food, tobacco, textile, printing and dyeing, feed, medicine, building material, wine, rubber, hospital

Properties of Steam Numericals v2 | Boiler | Steam - Scribd

steam from the boiler with a superheater is 350 o 16 . Problem 7: 1000 Kg of steam at a pressure of 16 bar and 0.9 dry is generated by a boiler per hour Problem 8: Feed water enters a boiler at 60 o. C at a bar is generated in a boiler . Dry

UNIT-III

At pressure 0.006112 bar , the melting and boiling point temperatures become equal . Wet steam : If 1 kg of wet steam is heated mf kg receives the latent heat of 

ME 24-221 THERMODYNAMICS I Solutions to - Andrew.cmu.edu

Dec 1, 2000 11.4 A steam power plant operating in an ideal Rankine cycle has a high pressure of 5. MPa and a low pressure of 15 kPa. of at least 95% and the turbine power generated should be 7.5 MW. Find the necessary boiler exit temperature and the total mass flow rate. T/wT = 7.5 × 1000 /1556.3 = 4.82 kg /s.

edexcel national certificate/diploma - Freestudy.uk

steam temperatures and pressures , dryness fraction, steam flow rate, fuel produced at high pressure and then used to drive a turbine and electric process steam is usually dry or wet so many boilers do not have a superheater . A steam boiler produces 0.2 kg /s at 50 bar and 400oC from water at 50 bar .. TEMP oC 0.9 .

thermal systems and applications - SlideShare

May 16, 2018 The steam is also super heated at constant pressure in 13 Entropy of wet and . h 44.72 130 509.8 m/s 79 Solution: Initial pressure of steam , p1 = 16 bar , .. kg of wet steam 0.9 kg is the dry steam and 0.1 kg water particles then x = 0.9 . . The heat supplied by the boiler per kg of steam generated Heat 

Boiler - SlideShare

Dec 4, 2014 Boiler presentation , subject Thermodynamics-II for Mechanical Engineering. Steam generated in shell can be tapped through a steam stop valve placed on the steam pressure1000 kg per hour and maximum steam pressure up to 10 bar . Some important accessories are Feed pump Superheater

ME 211 CH 3 Example Solutions

From Table A-3: p=0.8 bar . T = 93.50 °C. T = 96.71°C p= 0.9 bar . 0.9 . 0.834. 0.8 2) A rigid tank with a volume of 2.5 m3 contains 5 kg of saturated liquid-vapor mixture of water at 75°C. Now the water is slowly heated until the liquid in the .. transferred to the room when the steam pressure drops to 100 kPa. Also Page 16

Solutions - CSuN

Steam enters the turbine at 10 MPa and 500oC and is cooled in the The constant pressure heating in the steam generator shows the path of an The condenser heat rejection, ql = |h1 h4| = |191.81 kJ/ kg 2089.7 kJ/ kg | xout = 0.9 79. . of steam flowing through the boiler and (b) the thermal efficiency of the cycle.

Engineering Thermodynamics | Zeeshan Sohail - Academia.edu

The flue gases after passing around boiler tubes and superheater tubes in the .. The vapour at low temperature and pressure (state 'M') enters the 1000 kg of steam at a pressure of 16 bar and 0.9 dry is generated by a boiler per hour.

Steam Boilers

The grate, generally, consists of cast iron bars which are spaced apart so that air .. When the boiler is strongly heated, the steam generated carries a large quantity . the tubes of the combustion chamber walls and then enters the superheater . A Lancashire boiler generates 2400 kg of dry steam per hour at a pressure .

Problem Set Solutions

energy of the mercury; the energy balance, made over the time for the . process to take . Steam at 3 MPa, 300°C leaves the boiler and enters the high- pressure .

Untitled - KU

(Problen 10.16 in the book) The turbine of a steam power plant operating on a 10- 16 A simple ideal Rankine cycle with water as the working fluid operates between the specified subcooled by 6.3°C. The boiler is sized for a mass flow rate of 20 kg /s. net power produced by the cycle, and the thermal efficiency.

APPLIED THERMODYNAMICS D201 SELF ASSESSMENT

superheater and the rate of heat transfer to the boiler including the . Steam is extracted for feed heating purposes at pressures of 30 bar and 3.0 water enters the pump as a saturated liquid at 0.03 bar , and enters the boiler as a P1 = 0.9 ( h3 h3') = 150.3 kJ/ kg The remaining dry saturated steam then flows at constant.

Paper 2 - Set B Key 14th NATIONAL CERTIFICATION

Aug 24, 2013 A boiler generates 5 TPH of steam at an efficiency of 78 %. Condensate, at 3 bar pressure & 160°C, when exposed to . 19.85 * 106 = 300 * 0.86 * 1000 * 0.65 * T wants to install a de- superheater to convert superheated steam Enthalpy of dry saturated steam - 660 kcal/ kg . Dryness fraction. - 0.9 .

AME 50531: Intermediate Thermodynamics Homework Solutions

CPIG air enters and isentropic nozzle at 1.30 atm and 25C with a velocity of 2.5 m/s. Consider a steam turbine power plant operation near critical pressure , from the turbine, wt = h1 h3 = 4069.80 kJ/ kg 2235.04 kJ/ kg = 1834.76 kJ/ kg . ( 16 ) . The boiler pressure is 1000 psia, the reheater pressure bAr = 0.08664.

Applied Thermodynamics Question Bank Unit 1

Steam at 9 bar and 0.9 dry is supplied is an engine where it expands boiler generating 500kg/hr of steam at10.5 bar pressure and 0.97 dryness Mass of dry flue gases :10kg/ kg of fuel Temperature of steam leaving the super heater = 250 A steam turbine plant operates on Rankine cycle with steam entering turbine at 

Specific Steam Consumption - an overview | ScienceDirect Topics

Hence, these plants operate on high- pressure and high-temperature steam cycles. . is the Rankine cycle with dry saturated steam supplied by a boiler to a power unit, .. The superheater and reheater heat transfer surfaces absorb heat from the . The steam entered to the turbine at 8 bar ,a (8.16 kg /cm 2 ) and 170.4° C and 

Solved: 1. Steam Enters A Heat Exchanger At 1.5 MPa And 320

The condensed steam leaves the heat exchanger as saturated liquid at 1.5 enters this system at the first inlet with a pressure and temperature of 10 bar Obtain properties of steam at inlet pressure p -1.5MPa and at inlet temperature 7i -320°C from super - heated water tables h-3081.3kJ/ kg Obtain properties of steam at 

Thermodynamics - Routledge

A compressor takes in carbon dioxide at a pressure of 1 bar and temperature. 20 ° C and .. to100 ° C. The density of water is 1000 kg m 3 and its specific heat capacity is . Dry steam at 100 ° C enters a spray condenser at the rate of 2.1 kg min 1. .. system but each of its component parts such as the boiler , superheater , .

properties of steam - Heat Engines

dry steam (gas) and moisture (water), it possesses properties like those of gases : namely, pressure , volume, temperature, internal energy, enthalpy and entropy. But the pressure .. The superheater is heated externally by the furnace . kg of steam is generated by the boiler in one hour, find the quantity of heat supplied per.

GET Support & Price